Back to the Products page
Installation Guide

Cable Guide

3G2.5 · 3G6 · 4G4… This is the question we are asked most before anyone buys an appliance: "Is my existing cable enough?" On this page we explain step by step what cable cross-section is, how to identify the cable you already have, and which Veito model needs which cable. You do not have to be an electrician.

⚠️
Safety first. Before you look at the cable, switch off the main breaker. This page was written so that you can "identify the cable you already have" — running cable, consumer-unit and fuse work is a job for a qualified electrician. We install the appliance; if a new line is needed we discuss it together during the survey. If you are unsure about the cable, do not try it yourself — send us a photo.
Quick Answer

What is cable cross-section, and how many mm² does an instant water heater need?

Cable cross-section is the thickness, in square millimetres (mm²), of each copper conductor inside the cable. The thicker the conductor, the more current it carries and the less it heats up. Instant water heaters are high-power appliances, so a lighting or socket cable is often not enough.

Official figures: Blue S / Blue E4G4 NYM (3×32A fuse) · Flow E93G6 NYM (40A) · Flow E7 · Glow · V12003G2.5 NYM (32A). These are the minimum requirements; if the run is long your electrician may recommend the next size up.

Deniz Teknik · Authorised Veito Service · Antalya  ·  0242 311 31 30  ·  WhatsApp
30 Seconds

If you would rather not bother: send us a photo

You do not have to read everything below. Send a clear photo of the cable end on WhatsApp and we will look at it and tell you — free of charge.

1

Switch off the main breaker

If you are going to touch the cable, first switch off the main breaker at the consumer unit. If you are only going to look, touch nothing — a photo from a distance is enough.

2

Photograph the marking

On the grey/white outer sheath of the cable there is a marking such as "NYM-J 3G2.5" . Take the photo close enough to read it. If the marking has worn away, photograph the cut end of the cable so the number of cores is visible.

3

Send it on WhatsApp

Add which appliance you have in mind . Is the cable enough, is the fuse right, is a new line needed — we will tell you honestly.

Method 1

Read the marking on the cable

This is the most reliable method. There is a marking repeated along the outer sheath of the cable. It looks like this:

NYM-J 3G2,5 mm²
number of cores  ·  cross-section of each core  ·  unit (square millimetres)
PartWhat it meansExample
NYMCable type — a fixed indoor installation cable with a rigid PVC sheath. It is the standard cable used on instant water heater circuits.NYM, NYA, NHXMH
-JThere is a green-yellow earth core. -O means there is no earth — not to be used in a bathroom.NYM-J
3 · 4 · 5Number of cores (conductors). How many separately insulated conductors come out of it.3G… · 4G…
Gmeans the earth is included in the core count. X means there is no earth core.3G2.5 · 3X2.5
2,5 · 4 · 6Cross-section. The copper thickness of each core, in mm². This is the number you are actually looking for.…2,5 · …4 · …6

So 3G2,5 = 3 cores (one of them earth), 2.5 mm² each.   4G4 = 4 cores (3 phases + earth), 4 mm² each.   On some cables you will also see 3×2,5 written; it means the same thing — in our correspondence we use the 3G2,5 format.

3G2.5 · 3G6 Single-phase — 220V 4G4 Three-phase — 380V

This is what you see when you cut the cable. The orange part in the middle is copper and around it is insulation. The colour arrangement can differ from building to building — what you should really rely on is the marking on the sheath.

Method 2

If the marking has worn away: core count and colours

On older cables the marking on the sheath has often worn away. In that case look at the cut end of the cable: how many separate coloured conductors come out of it?

Brown
Live (the conductor bringing the electricity)
Light blue
Neutral (return conductor)
There is a green-yellow
Earth — compulsory in a bathroom
Black
2nd phase (on three-phase lines)
Grey
3rd phase (on three-phase lines)
What you seeWhat it meansWhich appliance it could be
3 coresBrown + blue + green-yellow → single-phase (220V) line.Flow E7 · Glow · V1200 · (Flow E9 if the cross-section is 6 mm²)
4 coresBrown + black + grey + green-yellow → three-phase (380V) line, 3 phases + earth.Blue S · Blue E
5 cores3 phases + neutral + earth. A three-phase line that also has a neutral.Blue S · Blue E (the neutral core is left unused)
2 coresNo earth. For an instant water heater it cannot be used.None — a new line is essential

Do not trust the colours blindly. Before 2000 the colour standard was different (red/yellow/blue for phases, black for neutral) and in some installations the colours were used incorrectly. Colour is a clue; the reliable information is the marking on the sheath and the electrician's measurement.

Method 3

How do you measure the thickness

If there is no marking and the colours are unclear, what is left is measuring the thickness of the copper conductor. On single-core (rigid, solid copper) cables this is easy: measure the diameter of the copper conductor and find the cross-section in the table below.

1.4 mm 1.5 mm² not enough 1.8 mm 2.5 mm² Flow E7 · Glow · V1200 2.3 mm 4 mm² Blue S · Blue E 2.8 mm 6 mm² Flow E9 3.6 mm 10 mm² main riser

The drawing is to scale (the proportions between them are correct), but it grows and shrinks with the screen size — do not hold a ruler against the screen, measure the cable.

Cross-sectionCopper conductor diameterWhere it is usually foundAt Veito
1.5 mm²≈ 1.4 mmLighting circuit, ceiling-light dropNot enough
2.5 mm²≈ 1.8 mmSocket circuit, washing machine / dishwasherFlow E7 · Glow · V1200
4 mm²≈ 2.3 mmThree-phase appliance circuit, electric ovenBlue S · Blue E (4G4)
6 mm²≈ 2.8 mmHigh-power single-phase appliance circuitFlow E9 (3G6)
10 mm²≈ 3.6 mmFlat supply / main riserMore does no harm

How to measure: Switch off the main breaker. Hold a vernier caliper against the stripped copper conductor at the end of the cable. If you have no caliper, press the copper conductor onto a sheet of paper, mark the impression and measure it with a ruler — since even a 0.2 mm error can change the cross-section, the result is approximate, so have your electrician confirm it.
⚠ On multi-strand (twisted, flexible) cables this method does not work: there the cross-section is the sum of dozens of fine strands. That type of cable must be measured by an electrician.

Matching

Which appliance needs which cable need?

The figures below are each model's minimum requirement. They are the official values printed on the appliance rating plate and in the user manual.

ModelOutputSupplyCableBreakerNote
Blue S21 kW380V three-phase4G4 NYM3×32 AA new line from the consumer unit is essential
Blue S 24 kW24 kW380V three-phase4G4 NYM3×32 ABespoke project work
Blue E21 kW380V three-phase4G4 NYM3×32 ASame line as the Blue S
Flow E99 kW220V single-phase3G6 NYM40 AWill not run from a socket
Flow E77 kW220V single-phase3G2.5 NYM32 ACan be spurred off an existing socket circuit
Glow8 kW220V single-phase3G2.5 NYM32 AShower unit
V12008 kW220V single-phase3G2.5 NYM32 AShower type, shower set included

4G4 = 4 cores × 4 mm² (3 phases + earth)  ·  3G6 = 3 cores × 6 mm²  ·  3G2,5 = 3 cores × 2.5 mm². If the run is long (a long distance between the consumer unit and the appliance) your electrician may recommend the next size up — that is not a shortcoming but a voltage-drop calculation.

Take care

The 6 mistakes we see most in the field

The same mistakes have come our way for twenty years. Check these before you buy an appliance — you will save both money and headaches.

1 · Feeding a high-power appliance from a socket circuit

The Flow E9 and the Blue series will not run from a socket. A socket circuit is usually 2.5 mm² and carries other loads as well. For these appliances a separate, new line from the consumer unit to the appliance is run. The Flow E7 · Glow · V1200 can be fed from a suitable socket circuit.

2 · Thin cable, bigger fuse

This is the most dangerous mistake. The fuse protects the cable, not the appliance. If you fit a large fuse to a thin cable, the cable heats up and it can end in a fire without the fuse ever tripping. The right way round is: first upgrade the cable, then choose the fuse to match.

3 · A line with no earth

A two-core line (brown + blue) has no earth. An appliance without an earth must not be operated in a wet room. There must also be a residual current device (life protection) in the consumer unit. If there is none, the electrician must add one before the appliance is installed.

4 · Joining the cable midway

Lines joined inside a junction box to extend the cable heat up at the joint under high load. Wherever possible, an instant water heater circuit should be a single unbroken run from the consumer unit to the appliance.

5 · Aluminium cable

At the same cross-section aluminium carries less current than copper and works loose in terminal connections over time. On an instant water heater circuit we use copper .

6 · "There was a boiler here, its cable is still there"

A boiler's electrical supply is usually thin(a boiler draws little electricity, it heats with gas). If an instant water heater is going in its place, that cable is usually not enough. The plumbing can be reused as it is, but the electrical line is renewed.

Have us check your cable

If you are undecided, do not struggle with it. Send the three photos below on WhatsApp; we will tell you honestly which appliance can be fitted, whether a new line is needed and roughly what it will cost. This check is free of charge.

📷 1 · The cable endThe cable end where the appliance will go — close enough to read the marking on it.
📷 2 · The consumer unitOne shot showing the whole board — how many fuses there are and whether you have three-phase, we can tell from that.
📷 3 · The fuse markingThe marking on the fuse that will feed the appliance (such asC32, C40 and so on).
Frequently Asked

What people ask about cable

Can I run the cable myself?
Consumer-unit and cable work is a job for a qualified electrician — both for safety and for the appliance's warranty. We carry out the appliance installation ; if a line is needed we tell you at the survey and, if you like, we will share the tradespeople we trust on WhatsApp.
My cable is 2.5 mm², can I fit a Flow E9?
No. The Flow E9 needs 3G6 (6 mm²) and a 40 A fuse. With the 2.5 mm² line you already have, a Flow E7 (7 kW) can be fitted — its body and display are the same as the E9, the difference is the power. If you do not want a new line run, the E7 is the right choice.
My fuse is 16A, will the appliance work?
If the fuse is smaller than the current the appliance draws, it will trip while the appliance is running. But the answer is not to fit a bigger fuse — first you check whether the cable can carry that current. If the cable is suitable, the fuse is changed to 32A / 40A / 3×32A depending on the model; if the cable is thin, the cable is renewed first.
Do I have three-phase (380V) at home, and how can I tell?
If there is a three-pole breaker (three levers joined together) in the consumer unit and a thick 4- or 5-core cable comes into the flat, you have three-phase. Three-phase is present in every building put up after 2000. If you are not sure, send a photo of the board and we will look at it.
If I remove the boiler and fit an instant water heater, will its cable be enough?
Usually not. A boiler uses electricity only for its board and pump and heats with gas, so its line is thin. An instant water heater, on the other hand, heats entirely with electricity and nothing else. The plumbing can usually be reused as it is — on the Products page you can see real installation photos of units fitted in place of a boiler — but the electrical line is renewed.
What is the difference between NYM and NYA?
NYM is a ready-made sheathed installation cable carrying several cores together — it is run into the wall or a conduit. NYA is a single-core cable with no sheath; the cores are pulled separately through a conduit. Either can be used; what matters is the cross-section and and the presence of an earth core.
🛟
One last reminder. This page is for guidance; no final decision is made without seeing your installation on site. Have electrical work done by a qualified electrician and keep a residual current device in the consumer unit. For appliance installation and warranty matters: Deniz Teknik — Veito authorised service, Antalya.